POWDER LEVEL CHECK SETUP (Deluxe model only)
1) Place the Powder Level assembly
into the powder hopper.
2) Locate the wire lead for the
Powder Detect Sensor and plug
the wire harness into the sensors.
3) Verify the wire harness is
plugged in correctly by activating
the sensor and verifying the
corresponding light turns from
green to red on the Control Panel.
4) Adjust the Stop up or down on the Powder Float to the desired level by
sliding the o-rings on each side of the Stop up or down.
OPERATION
When the level of powder becomes low, the stop on the top of
the Powder Float should trip the sensor.
POWDER SAFEGUARD DIE SETUP (Deluxe model only)
1) Install Lock-N-Load bushing
(sold separately) onto Powder
Safeguard Die.
2) Screw the brass tip nearly all the way
onto the stem by holding the tip and
top knurl.
3) Cycle press to hold at the top of
the stroke (the shellplate is as high
as possible).
4) Install Powder Safeguard Die into
the press next to the powder drop.
Screw down the Powder Safeguard
Die until approximately
1
8” above the
shell plate.
5) Place a case with the correct
powder charge under the safe guard die. Begin to cycle the press until
resistance is met. The press should lock up (not continue through a
full cycle).
6) Unscrew the brass tip slightly, while holding the top knurl, and try
to cycle the press again. Repeat until the press cycles. Unscrew an
additional turn and verify press cycles.